在线一区,探花私拍一区二区,黄色中国少妇淫荡视频,国产美女精品人人做人人爽

    您好,歡迎進入南京惠言達電氣有限公司網(wǎng)站!
    一鍵分享網(wǎng)站到:
    您現(xiàn)在的位置:首頁 >> 技術(shù)文章 >> miniBOOSTER惠言達增壓器HC2-5.0-B-1F笑容銷售
    miniBOOSTER惠言達增壓器HC2-5.0-B-1F笑容銷售
    瀏覽次數(shù):1071發(fā)布日期:2020-07-03

    HC2-F

    Data:

     

    HC2-F versions: 13 different intensification factors

    PIN: 20–207 bar

    PH: 800 bar maximum

    PRETURN: As low as possible (return pressure to tank)

    POUTLET: PH = (PIN – PRETURN) i (intensification)

    Mounting: Flange, manifold system miniBOOSTER pattern

    Weight: 1.2 kg.

     

    Model versions:

    A model = no dump valve
    B model = with dump valve
    G model = direct proportionally controlled

    Material certificate 3.1 on request

    Description

    The HC2-F is a variant of the HC2 for flange mounting on the low pressure side. The entire pattern is a miniBOOSTER design. It is a compact unit weighing only 1.2 kg. It is ideal for use in a variety of applications where building and maintaining high pressure is required.

    The HC2-F raises supplied pressure to a higher outlet pressure and automatically compensates for consumption of oil to maintain the high pressure. Adjustment of the outlet pressure is carried out by varying the supplied pressure.

    Flow rates

    Intensification factor
    i
    Max. intensified outlet flow
    l/min
    Max. inlet flow
    l/min
    1.23.58.0
    1.54.212.0
    2.03.212.0
    2.22.912.0
    2.52.713.0
    2.82.513.0
    3.22.515.0
    4.02.014.0
    5.01.614.0
    6.61.313.0
    9.00.913.0
    13.00.612.0
    20.00.312.0

    Functions

    The basic operation is illustrated in the function diagram. Oil is fed through the directional valve CV to the IN port, flowing freely through the check valves KV1, KV2 and DV to the high-pressure side H. In this condition maximum flow through the booster is achieved giving a fast-forward function.

    When pump pressure is reached on the high-pressure side H, valves KV1, KV2 and DV will close. The end pressure will be achieved by the oscillating pump unit OP. The unit will automatically stall when end pressure on the high-pressure side H is reached. If a pressure drop on the high-pressure side exists due to consumption or leakage, the OP valve will automatically operate to maintain the end pressure.

    Function diagram

    2-105-01

    Download

    Dimensions

    Dimension drawing 2-135-01

    Download

    Connection types

    ConnectionIN / RH
    1FFlange1/4" BSPP
    2FFlange9/16-18 UNF